They are intended for installation in bathrooms, laundries, living and office spaces. They can be mounted on a wall or ceiling.
Construction
EDM fans are adapted to work in any position and assembly directly in ventilation ducts (Ø90, Ø100 and Ø125). EDM fans are made of plastic. The shower enclosures are designed for the EDM 100S-12V and EDM 100C-12V fans, powered with 12V voltage with protection degree of IP 57, and have protection against electric shock in class III. Ventilators with hygrostat (H version) – IP44 protection.
Electric engine
Electric motor 230 V, 50 Hz with ball bearings. The motor has protection against electric shock in class II, winding insulation in class B, IP40 degree. Adapted to work in temperatures up to 40 ° C.
|
Typ
|
nmax [obr./min]. |
Pobór mocy [W] |
Napięcie [V] |
Natężenie [A] |
Qmax [m3/h] |
Δpmax [Pa] |
[db(A)] | Masa [kg] |
| EDM 80 | 2350 | 9 | 230 | 0,07 | 80 | 24 | 33 | 0,4 |
| EDM 100 | 2450 | 13 | 230 | 0,08 | 95 | 33 | 40 | 0,5 |
| EDM 200 | 2500 | 25 | 230 | 0,15 | 180 | 50 | 46 | 0,9 |
| Wersja | EDM 80 | EDM 100 | |||||||||||
| Typ | NZ | NTZ | SZ | TZ | HZ | CZ | CTZ | MZ | ECZ | CHZ | VMZ | RZ | CRZ |
|
Control lamp
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
|||
|
Time delay
|
•
|
•
|
•
|
||||||||||
|
Regulated time delay
|
•
|
•
|
•
|
•
|
|||||||||
|
Automatic louvre
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
||||||
|
Light sensor
|
•
|
||||||||||||
| Regulated humidity sensor |
•
|
•
|
|||||||||||
|
Cord switch
|
•
|
•
|
•
|
•
|
|||||||||
|
Window installation
|
•
|
||||||||||||
|
Bearings
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|
| Wersja | EDM 200 | ||||||
| Type | SZ | TZ | HZ | CZ | CTZ | CHZ | CRZ |
|
Control lamp
|
•
|
•
|
•
|
•
|
•
|
•
|
|
|
Time delay
|
•
|
•
|
|||||
|
Regulated time delay
|
•
|
||||||
|
Automatic louvers
|
•
|
•
|
•
|
•
|
|||
|
Light sensor
|
|||||||
|
Regulated humidity sensor
|
•
|
•
|
|||||
|
Cord switch
|
•
|
•
|
|||||
| Window installation | |||||||
|
Bearings
|
•
|
•
|
•
|
•
|
•
|
•
|
•
|