{"id":14496,"date":"2016-01-21T11:36:15","date_gmt":"2016-01-21T11:36:15","guid":{"rendered":"http:\/\/www.hts.com.pl\/bez-kategorii-en\/centrala-rekuperacyjna-rli-rle\/"},"modified":"2018-01-09T11:23:36","modified_gmt":"2018-01-09T11:23:36","slug":"centrala-rekuperacyjna-rli-rle","status":"publish","type":"post","link":"https:\/\/test.hts.com.pl\/en\/centrale-rekuperacyjne-i-wentylacyjne-en\/centrala-rekuperacyjna-rli-rle\/","title":{"rendered":"air-handling unit RLI-RLE"},"content":{"rendered":"<p>Construction<br \/>\nThe housing of the RLI \/ RLE control panels is made entirely of a double layer of steel sheet 2&#215;1 mm thick, galvanically zinc plated, in a frameless technology &#8211; this eliminates the phenomenon of the so-called cold bridges. Thermal and acoustic insulation with mineral wool with a thickness of 40 mm and a density of 88 kg \/ m3<br \/>\nIn the RLI \/ RLE units there is a throttle valve with a spring return actuator installed. As a standard, the units are equipped with EU5 class panel filters at the inlet air inlet and EU7 at the inlet air inlet. In order to control the state of contamination of the filters, pressure controls have been used, which are included in the automation equipment of the control panel. Exceeding the admissible values \u200b\u200bwill display a message informing you that filters must be changed.<br \/>\nHeat recovery is carried out using a rotary exchanger.<\/p>\n<p>Fans<br \/>\nIn the RLI \/ RLE type control panels, energy-saving JETTEC fans with motors adapted to be adjusted by inverters and JETTEC EC electronically commutated. The diagonal design of the rotor ensures the highest efficiency parameters in this class of fans.<br \/>\nIn RLE type units, JETTEC fans are supplied as separate components for installation in the duct.<\/p>\n<p>Drive and control<br \/>\nAll models of RLI \/ RLE are powered by three-phase 400V, 50Hz. Equipped with a complete automation to control the operation of the control panels (including multilevel dampers, anti-freeze protection, EC regulators, service switch)<\/p>\n<p>Rotary exchanger<br \/>\nThe efficiency of heat recovery in RLI \/ RLE units is up to 82%. The rotary exchanger used in them is made of wavy aluminum sheet wound on a cylinder. The rotary movement of the exchanger provides a belt-driven motor. The heat exchange plane resulting from rotational motion is much higher than in the case of standard cross-flow exchangers.<\/p>\n<p>The panels can be mounted on the roof using a roof cover (optional).<\/p>\n<p>The most important features:<\/p>\n<p>compact sizes of RLE panels<br \/>\n4 basic series of types in 6 variants<br \/>\nefficiency up to 10,000 m3 \/ h<br \/>\nrotary air exchanger (efficiency up to 82%)<br \/>\ncomplete automation system with control panel<br \/>\nintegrated multi-faceted dampers with an actuator<br \/>\nstandard and electronically commutated (EC) motors<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Construction The housing of the RLI \/ RLE control panels is made entirely of a double layer of steel sheet 2&#215;1 mm thick, galvanically zinc plated, in a frameless technology [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":12993,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[179,182],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.3 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>air-handling unit RLI-RLE - hts<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"air-handling unit RLI-RLE - hts\" \/>\n<meta property=\"og:description\" content=\"Construction The housing of the RLI \/ RLE control panels is made entirely of a double layer of steel sheet 2&#215;1 mm thick, galvanically zinc plated, in a frameless technology [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/\" \/>\n<meta property=\"og:site_name\" content=\"hts\" \/>\n<meta property=\"article:published_time\" content=\"2016-01-21T11:36:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-01-09T11:23:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/test.hts.com.pl\/wp-content\/uploads\/2016\/01\/rle.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"523\" \/>\n\t<meta property=\"og:image:height\" content=\"545\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alicja Siroic\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alicja Siroic\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/\",\"url\":\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/\",\"name\":\"air-handling unit RLI-RLE - hts\",\"isPartOf\":{\"@id\":\"http:\/\/test.hts.com.pl\/#website\"},\"datePublished\":\"2016-01-21T11:36:15+00:00\",\"dateModified\":\"2018-01-09T11:23:36+00:00\",\"author\":{\"@id\":\"http:\/\/test.hts.com.pl\/#\/schema\/person\/d8d4403465db7da3b92c3581bf70ef47\"},\"breadcrumb\":{\"@id\":\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"http:\/\/test.hts.com.pl\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"air-handling unit RLI-RLE\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\/\/test.hts.com.pl\/#website\",\"url\":\"http:\/\/test.hts.com.pl\/\",\"name\":\"hts\",\"description\":\"ca\u0142y \u015bwiat wentylacji\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\/\/test.hts.com.pl\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"http:\/\/test.hts.com.pl\/#\/schema\/person\/d8d4403465db7da3b92c3581bf70ef47\",\"name\":\"Alicja Siroic\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"http:\/\/test.hts.com.pl\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/04f1887f0572d0ba30f90049980b9694?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/04f1887f0572d0ba30f90049980b9694?s=96&d=mm&r=g\",\"caption\":\"Alicja Siroic\"},\"url\":\"https:\/\/test.hts.com.pl\/en\/author\/alicja-siroic\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"air-handling unit RLI-RLE - hts","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"air-handling unit RLI-RLE - hts","og_description":"Construction The housing of the RLI \/ RLE control panels is made entirely of a double layer of steel sheet 2&#215;1 mm thick, galvanically zinc plated, in a frameless technology [&hellip;]","og_url":"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/","og_site_name":"hts","article_published_time":"2016-01-21T11:36:15+00:00","article_modified_time":"2018-01-09T11:23:36+00:00","og_image":[{"width":523,"height":545,"url":"https:\/\/test.hts.com.pl\/wp-content\/uploads\/2016\/01\/rle.jpg","type":"image\/jpeg"}],"author":"Alicja Siroic","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Alicja Siroic","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/","url":"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/","name":"air-handling unit RLI-RLE - hts","isPartOf":{"@id":"http:\/\/test.hts.com.pl\/#website"},"datePublished":"2016-01-21T11:36:15+00:00","dateModified":"2018-01-09T11:23:36+00:00","author":{"@id":"http:\/\/test.hts.com.pl\/#\/schema\/person\/d8d4403465db7da3b92c3581bf70ef47"},"breadcrumb":{"@id":"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/test.hts.com.pl\/centrale-rekuperacyjne-i-wentylacyjne\/centrala-rekuperacyjna-rli-rle\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"http:\/\/test.hts.com.pl\/"},{"@type":"ListItem","position":2,"name":"air-handling unit RLI-RLE"}]},{"@type":"WebSite","@id":"http:\/\/test.hts.com.pl\/#website","url":"http:\/\/test.hts.com.pl\/","name":"hts","description":"ca\u0142y \u015bwiat wentylacji","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/test.hts.com.pl\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Person","@id":"http:\/\/test.hts.com.pl\/#\/schema\/person\/d8d4403465db7da3b92c3581bf70ef47","name":"Alicja Siroic","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"http:\/\/test.hts.com.pl\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/04f1887f0572d0ba30f90049980b9694?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/04f1887f0572d0ba30f90049980b9694?s=96&d=mm&r=g","caption":"Alicja Siroic"},"url":"https:\/\/test.hts.com.pl\/en\/author\/alicja-siroic\/"}]}},"_links":{"self":[{"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/posts\/14496"}],"collection":[{"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/comments?post=14496"}],"version-history":[{"count":2,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/posts\/14496\/revisions"}],"predecessor-version":[{"id":15652,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/posts\/14496\/revisions\/15652"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/media\/12993"}],"wp:attachment":[{"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/media?parent=14496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/categories?post=14496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/test.hts.com.pl\/en\/wp-json\/wp\/v2\/tags?post=14496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}